UPSMON Manuale Utente Configurazione per utenti esperti • 75
VIII. Configuration for expert users
1. Manual changes of the UPSMON.INI parameters
The UPSMON.INI configuration file includes some fields that are possible to modify by editing the file.
SYSTEM section:
[System]
OEMMode=0
1 Enables the configuration menu and the functions menu;
4 Disables the display of the Upsagent icon on the task bar;
It is possible to use a combination of these i.e. 1+2 =3.
DebugMode=0
1 Enables the view of some extended parameters in the debug mode;
3 Decodes the entire UDP packet in the TCP/IP communication;
ShutdownType=1
0 Executes only the system shutdown (computer with AT power supply);
1 Default executes system shutdown and turns off the computer power supply (ATX power supply);
In the SERIAL_00 section:
[Serial_00]
CheckRate=1
Enables the time between one request and the next for the serial communication to be incremented. This is important if there is
communications loss due to a slow computer.
2. Console execution of Upsagent
The Upsagent service can be executed using various parameters:
¾ -debug to view all the data flow between the program and the UPS;
¾ -log to save the data flow shown in the file debug.log;
The file created can be used to solve any problems with the communication.
In Windows there are others parameters:
¾ -start to start the service;
¾ -stop to stop the service;
¾ -install to write the service in the Windows configuration registry;
¾ -remove to cancel the service from the Windows configuration registry;